Written per model, with the numbers we actually hold.
Most supplier websites say "CE and RoHS certified" and leave it there. This page lists which model is covered by which certificate, who the applicant is, and what is missing. If a figure is not here, we do not have it.
Which model, which file.
Read across a row to see everything that exists for that model. A dash means the report does not cover it — not that it failed.
| Model | CE-EMC | CE-LVD | LVD 2-43 | LVD 2-30 | EMF | RoHS | REACH SVHC | SCCP |
|---|---|---|---|---|---|---|---|---|
| JB-GX101 | Yes | Yes | — | — | — | Yes | Yes | — |
| JB-GX201 | Yes | Yes | — | — | — | Yes | Yes | — |
| JB-GX301 | Yes | Yes + 2-43 / 2-30 | Yes | Yes | Yes | Yes | Yes | Yes |
| JB-GX401 | — | — | — | — | — | Yes | — | — |
| JB-GX501 | — | — | — | — | — | Yes | — | — |
Scope of the CE certificates
AC 220–240 V~, 50/60 Hz versions only. All four certificates state the same rating: 20 W. The USB versions run at 12 V DC and sit outside this scope.
Why 2-43 and 2-30 matter
A shoe dryer is not obviously a "clothes drying appliance" or a "room heater" — but a notified body treated it as both, so GX301 carries both particular standards. That is unusual and worth asking your compliance team about.
Two applicants
The 2023 EMC and LVD main standards were applied for by the Shenzhen entity; the 2024 particular standards and chemical reports by the Zhongshan entity. If you need one letterhead for the whole file, tell us before the PI.
Certificate and report numbers.
Give any of these to your compliance team and they can verify them with the issuing lab.
| Item | Standard | Number | Model | Applicant | Date |
|---|---|---|---|---|---|
| CE-EMC | EN IEC 55014-1 / -2:2021 EN IEC 61000-3-2, EN 61000-3-3 | CTB230303040E-ZS | GX101 · GX201 · GX301 | Shenzhen | 2023-03-24 |
| CE-LVD | EN 60335-1:2012+A15:2021 EN 62233:2008 | CTB230301027S-ZS | GX101 · GX201 · GX301 | Shenzhen | 2023-03-24 |
| CE-LVD 2-43 | EN IEC 60335-2-43:2020+A11:2020 | CTB240731056SX-ZS | GX301 | Zhongshan | 2024-08-14 |
| CE-LVD 2-30 | EN 60335-2-30:2009+A13:2022 | CTB240604060SX-ZS | GX301 | Zhongshan | 2024-06-06 |
| EMF | EN 62233:2008 | CTB240527055EX | GX301 | Zhongshan | 2024-06-11 |
| RoHS | 2011/65/EU + (EU) 2015/863 | EFHZ19052354-CG-01 | GX101 – GX501 | Eurofins | 2019-06-12 |
| REACH SVHC | EC 1907/2006 · candidate list | DGC240523044NE01 | GX301 | Zhongshan | 2024-06-18 |
| SCCP (POPs) | (EU) 2019/1021 · limit 1,500 mg/kg | DGC240523044NE03 | GX301 | Zhongshan | 2024-05-30 |
| Packaging metals | 94/62/EC · Pb+Cd+Hg+Cr(VI) ≤ 100 mg/kg | DGC240615015WE02A | Colour box | Zhongshan | 2024-06-26 |
| Packaging oil | French Decree 2020-1725 | DGC240615015WE03A | Colour box | Zhongshan | 2024-06-26 |
Declaration of Conformity
A test certificate is not a DoC. The CE mark is affixed by the manufacturer after the technical file and the declaration are prepared — the labs say so on the certificates themselves. We issue a DoC against the model you order, naming the directives and the harmonised standards, together with the technical file. Ask for it with the PI so nobody is chasing paperwork at the port.
Shorter path — not no path.
The single most common misunderstanding about a 12 V shoe dryer, on both sides of the table.
| Directive / item | AC 220–240 V version | USB 12 V DC version | Reason |
|---|---|---|---|
| Low Voltage Directive | Applies — certified | Out of scope | LVD covers AC 50–1000 V and DC 75–1500 V; 12 V is below both |
| EMC | Applies — certified | Still applies | No voltage threshold in the directive |
| RoHS | Applies | Still applies | Substance restriction is independent of supply voltage |
| REACH | Applies | Still applies | Same |
| Charger | — | Carries the mains-side file | If we ship one, its CE and DoC are ours; if you source it, they are yours |
So "the USB version does not need certification" is wrong, and we will not say it. It needs less, and the split above is exactly what your compliance team should be given.
amfori BSCI · monitored, not "certified".
BSCI has no certificate — it produces a monitoring report. Ours is a full audit carried out on site by SGS in October 2025, semi-announced, covering the 13 performance areas. The product in scope is shoe dryers.
The report itself we share after confirming the current audit cycle with you, so you receive a live document rather than a superseded one. If your tender requires a specific cycle date, tell us the deadline and we will answer against it.
Four gaps, stated up front.
A buyer finds these anyway. Better from us, in writing, before the sample order.
No CE on GX401 / GX501
The 40 W models with fan and UV are not covered by any CE certificate. They ship with a 2019 RoHS report. If your market is the EU, quote GX101 / GX201 / GX301, or budget a test order for the 40 W unit before production.
The printed catalogue says 10 W
Our 2021 catalogue prints 10 W for the 20 W models. All four CE-LVD certificates state 20 W, and 20 W is what we quote and what goes on the PI and the carton label. If you hold the old PDF, treat its power column as superseded — and ask us for a corrected sheet for your file.
No ErP file
The timer versions have a standby draw. Whether ErP (2009/125/EC) applies to this product group is still open with our lab. If your customs broker asks for an ErP declaration, tell us and we will get a written position rather than improvise one.
SVHC list has moved on
The 2024 GX301 report tested 240 substances plus proposals against the candidate list of that date. ECHA updates the list twice a year — a strict buyer will want a re-test against today's list. We can quote that with an order.
Tell us the model and the market, and we send the matching set.